When sourcing a flanged non-rising stem gate valve for municipal water supply or building drainage pipelines, three selection criteria matter most: stem clearance requirements, flange standard compatibility, and pressure rating alignment. This flanged non-rising stem gate valve addresses all three. Manufactured from ductile cast iron with internal and external blue epoxy coating, it delivers reliable on-off control for water pipelines at 0–80°C operating temperature, available in PN10 or PN16 pressure ratings and sizes from DN50 to DN600. As a water valve designed for water supply, drainage, and sewage service, it combines a compact non-rising stem design with flanged connection strength and corrosion protection suited to municipal and industrial applications.

| Parameter | Specification |
|---|---|
| Valve body material | Ductile cast iron |
| Connection method | Flanged connection |
| Actuation mode | Manual handwheel |
| Stem structure | Non-rising, concealed stem |
| Coating | Internal and external blue epoxy anti-corrosion coating |
| Applicable media | Water (water supply, drainage, sewage) |
| Temperature range | 0–80°C |
| Pressure rating | PN10 / PN16 |
| Nominal size range | DN50 to DN600 |
| Function | Pipeline on-off control |

The non-rising stem of this flanged non-rising stem gate valve stays inside the valve body throughout operation. When the handwheel is rotated, the internal gate disc moves along the stem thread — the stem itself does not extend upward. This eliminates the overhead clearance requirement that rising-stem alternatives demand. For underground valve pits, basement mechanical rooms, and confined trench installations, the non-rising stem design allows standard installation without civil modification. If your available clearance above the valve centerline is restricted, this design determines whether the valve is installable without additional construction work.
Flanged connections provide higher connection strength than threaded alternatives for medium-to-large bore piping. Before finalizing procurement, confirm the flange standard, face type, and bolt circle dimensions match your existing pipeline. In international purchasing of pipe components, discovering after delivery that flange dimensions do not match installed pipe flanges is a common and costly problem. For renovation work where new valves must interface with established piping, confirm the specific standard with the supplier. Associated hardware including allen wrench compatible fasteners should match the project bolt specification.
A common mistake when selecting a flanged non-rising stem gate valve is choosing the highest pressure rating under the assumption that higher is always safer. Over-specifying at PN16 when the system operates at PN10 conditions adds unnecessary weight, cost, and may create flange class mismatches. In pipe system design, pressure class selection is based on maximum working pressure plus a design safety margin. Confirm your system design pressure and test pressure with your project engineer before selecting the rating.


This flanged non-rising stem gate valve is widely applied in municipal tap-water distribution pipelines, underground pipe networks, and pump station projects. Municipal valve pits are typically built to minimum dimensions with no overhead clearance for a rising stem. The non-rising stem design allows standard installation in these confined underground spaces. Engineering procurement teams report that ductile iron body construction and sealed stem design meet operational requirements of buried water infrastructure over extended service periods. Product drawings, flange dimension tables, and pressure parameter data sheets are available to support engineering review.
For residential building water supply and drainage pipe networks, this gate valve provides reliable isolation at branch connections and main line takeoffs. Flanged joints allow straightforward disassembly during maintenance — practical in buildings where periodic pipe servicing is routine. In factory circulating-water and sewage treatment pipelines, this valve provides stable on-off isolation within the 0–80°C temperature range. If your application involves media outside this range, confirm suitability with the supplier before finalizing the specification.
Compared to rising-stem gate valves, this flanged non-rising stem gate valve eliminates the vertical space requirement above the valve, protects the stem from external corrosion, and fits confined valve pits without additional civil accommodation. Compared to threaded small-bore gate valves, flanged connections deliver the connection strength and pressure integrity required for DN50 and larger piping. The ductile iron body with blue epoxy coating offers improved impact resistance over standard grey cast iron alternatives. The DN50–DN600 size range enables consolidated procurement across the full bore spectrum typically required in municipal and commercial water pipeline projects. Sample testing is supported and large-volume project pricing is negotiable.